作 者: ; ; ; ; ; ; ; (汪洋洋); (熊家政);
机构地区: 中南大学能源科学与工程学院
出 处: 《煤气与热力》 2003年第2期70-72,共3页
摘 要: 介绍了基于换向式蓄热燃烧的高温空气发生工艺,并进行了冷态实验。结果表明调节鼓风机和排烟机的开度,可调节高温空气流量,分流出口处空气流量调节范围为0~0.102m3 s,分流出口处空气压力调节范围为0~210Pa。 A new technology of high temperature air generator with remarkable savingenergy and lowpollution is introduced based on high cycle regenerative combustion. Coldstate experiment is carried out. The results show that coldend regulation can adjust airflow. The total regulation range of the outlet airflow is between 0 and 0.102 m3/s. The regulation range of the outlet air pressure is between 0 and 210 Pa.
领 域: [动力工程及工程热物理]