机构地区: 合肥通用机械研究院
出 处: 《发电与空调》 2013年第4期61-64,共4页
摘 要: 介绍了一种附带循环加热式热回收功能的水源热泵试验装置,阐述了它的测试原理、系统设计和试验方法,分析了系统运行过程中性能的动态变化特性,对一台样机开展了试验研究,结果表明,热采集器的热回收效率达19.5%。 This paper describes a equipment used to test a heat pump which cycling has heat recovery system, and expounds its test principles, system design and test method. Analysis the dynamic nmtative feature of the system during it working. Through the experiment on a prototype,the result show that the heat recovery efficiency of heat collector can be 19.5%.
领 域: [建筑科学]