摘  要: 变径毛细管在正向流动和反向流动时其制冷剂流量特性不同,因而可以作为节流元件代替现有冷暖空调器中使用的毛细管组件。为实现这一目的,利用制冷剂流量试验台,先测定原毛细管组件制冷、制热时的制冷剂流量特性,然后通过调整变径毛细管规格尺寸,使变径毛细管制冷、制热时的流量特性与原毛细管组件基本一致,再安装在空调器整机上进行整机性能对比试验。试验表明,在标准工况下,新空调器与原空调器相比,其制冷量减少0.5%,制冷能效比增加0.3%,制热量减少1.1%,制热性能系数增加1.4%。因此可以得出,变径毛细管经过精确匹配,完全可以作为节流元件代替现有冷暖空调器中使用的毛细管组件。 The refrigerant flow characteristics of variable diameter capillary in forward flow and reverse flow are different. It canbe used as a throttle device instead of the capillary module in heat pump air-conditioner. To achieve this goal, the refrigerant flow characteristic of the original capillary module for refrigerating and heating circulation was performed in the refrigerant flow experimental facility. The size of variable diameter capillary was adjusted to make its refrigerant flow performance is accordance with that of capillary module. The capability of air conditioner with variable diameter capillary and capillary module were tested respectively in the standard condition. The experimental results show that the performance of air-conditioner with variable diameter capillary compared to that of air conditioner with capillary module, the refrigerating capacity decreased by 0.5%, the energy efficiency ratio(EER) increased by O. 3% , the heating capacity reduced by 1.1%, the coefficient of performance (COP) increased by 1.4%. Hence, the higher flow performances of variable diameter capillary indicate that it can completely used as a throttle device instead of the capillary module in the heat pump air-conditioner after it matched exactly.

关 键 词: 变径毛细管 毛细管组件 冷暖空调器 流量特性

领  域: [机械工程] [机械工程]

相关作者

作者 陈淑环
作者 张亚琛
作者 陈秋晓
作者 林志英
作者 许程明

相关机构对象

机构 中山大学
机构 广州大学
机构 广州大学地理科学学院
机构 暨南大学
机构 深圳职业技术学院

相关领域作者

作者 何祥文
作者 黄晓宇
作者 董俊武
作者 刘佳宁
作者 石宝雅