机构地区: 五邑大学
出 处: 《实验科学与技术》 2012年第2期11-14,共4页
摘 要: 讨论了不同温度下PN结的正向伏安特性的测量方法,设计了利用TH-J型PN结正向压降温度特性测试仪研究PN结正向伏安特性曲线随温度变化的实验,定性地分析了PN结正向伏安特性随温度变化的规律;利用Excel进行指数拟合测定了波尔兹曼常数,并确定了常温下PN结的反向饱和电流,从而定量地描述PN结的正向伏安特性曲线,取得了较为准确的实验结果。 The measuring method of positive volt-ampere characteristics of PN junction at different temperature is introduced.The experiment of variation of positive volt-ampere characteristics of PN junction with temperature based on the instrument of model TH-J which is used to research the relation of PN junction forward voltage drop and temperature is designed.The Boltzmann constant and the reverse saturation current of the PN junction on normal temperature are measured.The positive volt-ampere characteristics of PN junction and its variation with temperature can be described quantitatively and qualitatively,and the good experiment results are reached.