作 者: ;
机构地区: 广东海洋大学
出 处: 《流体机械》 2006年第7期79-83,共5页
摘 要: 在不同的室内外温度情况下,对5台制冷量为2600W热泵型分体空调器进行了实验分析,研究了室内外温度对空调器的制冷能力、显热能力、能耗和能耗比EER等性能的影响规律。总结出:室外温度每上升1℃,制冷量平均下降25.3W,显热量平均下降20.2W,EER值平均下降0.035;室内温度每提高1℃,制冷量平均增加57.6W,显热能力增加26.6W,EER提高0.0515。 An experiment was analyzed on five heat pump detachable air- conditioner to study the influences of indoor and outdoor temperature on its refrigerating and sensible heat efficiency, energy efficiency and Energy Efficiency Ratio ( EER ) in the different of indoor temperature and outdoor temperature. The conclusion includes: 1 ). If the outdoor temperature rises by 1 ℃, the average refrigerating efficiency decreases by 25.3W, sensible heat efficiency falls by 15.1W and EER drops by 0.035; 2). If the indoor temperature rises by 1℃, the average refrigerating efficiency increases by 57.6W, sensible heat efficiency rises by 26.6W and EER rises by 0. 0515W.
领 域: [一般工业技术]