机构地区: 广州大学土木工程学院
出 处: 《广州大学学报(自然科学版)》 2005年第4期366-369,共4页
摘 要: 为了解火车站售票厅内的空气质量状况,采用便携式快速检测仪于2004年7月22~30日对广州火车站售票厅内的室内空气品质进行检测.检测的参数主要有CO、CO2、可吸入颗粒物(PM10)和总挥发性有机化合物(TVOC).所测室内CO2(775~1 578×10-6)和PM10(0.129-0.346mg·m-3)严重超标.结果表明:室内的污染水平高于室外. In order to find out indoor air quality(IAQ) condition in ticket halls in railway stations in the survey, the ticket hall IAQ had been investigated with the carry-home fast inspect instrument from July 22^nd to July 30th in Guangzhou Railway Station. The levels of Carbon monoxide, Carbon dioxide, Respirable particulates (PM10) and total volatile organic compound (TVOC) had been inspected. The levels of CO2(775 - 1 578 × 10^-6) and PM10(0. 129- 0.346 mg·m^-3) in the ticket hall exceeded IAQ standard, the levels of other contaminant were under the standard scope. It shows that the levels of indoor pollutant are higher than outdoors'.
领 域: [环境科学与工程]