机构地区: 广州大学土木工程学院
出 处: 《制冷》 2007年第2期81-84,共4页
摘 要: 通过分析,目前我国地铁站空调系统所采用的定风量模式存在能耗大、不能很好的调节地铁热环境的缺点,提出在地铁站采用变风量空调系统。而如何实现对地铁变风量空调系统的稳定控制,是实现地铁空调系统节能,同时保证地铁站环境舒适性的前提。 In view of the CAV air-conditioning system adopted in subway stations of our country costing heavy energy consumption,and not achieving a good adjustment for the thermal environment of the subway station,the VAV air-conditioning system is proposed.The premise of making good energy-efficiency effect while keeping the environment of the subway station comfortable is to keep stable control for the VAV air-conditioning system.